JBF5200

Graph Indicator in Fire Control Room


Product Features
1. Graph indicator in fire control room uses Chinese interface. When connected to power, the indicator directly enter into the interface. When interface is turned off, automatically the indicator is power off.
2. Graph indicator in fire control room uses red LED indicators for alarm, automatic control, status, and supervision states, and yellow indicators for fault and disable states.
3. Graph indicator in fire control room receives fire alarm and auto control signals. It enters fire or auto control states within 3s, and displays relating alarm messages graphically.
4. Graph indicator in fire control room can query and display the physical addresses, address notes, and corresponding status information of fire equipment within the monitored subjects’ system in real time.
5. Graph indicator in fire control rooms can monitor and display networking conditions of fire alarm control units in real time. It can remotely transfer and display alarm information.
6. Graph indicator cannot reset control units, or modify system settings and on/off states of auto control devices.
7. After fire alarm control unit reports fire, graph indicator in fire control room displays building general plan, floor plan and relevant system drawings of the fire zone in real time.
8. Graph indicator in fire control room has specific indicating functions of states corresponding fire alarm signals, supervisory signals, status signals, disable signals, fault signals, etc.
9. Graph indicator in fire control room shows fire alarm and status information within 10s and information of other states within 100s.
10. When receives fire alarm signals and auto-control signals, graph indicator in fire control room can display building location, building plan and the specific location, alarming time and information of the alarming device.
11. There is a separate area in the top left corner of the graph indicator to show FIRST ALARM address.
12. Graph indicator in fire control room can search alarming address and relevant information manually.
13. When receives fire alarm signals and auto-control signals, graph indicator in fire control room can display alarm plan of the alarm reporting device. When there are reporting devices located in different floor plan, the information can be loop displayed automatically or manually.
14. Graph indicator in fire control rooms can be manually reset.
15. Graph indicator in fire control room gives out audio and visual alarm when receives alarm, auto-control and fault signals.
16. Graph indicator in fire control room records and stores various alarm information.
17. Graph indicator in fire control room can record duty log, operator, product maintenance information, and devices real-time states in each protective zone. Records include operator code, product maintenance content and time, various devices’ real time information, system entering and exiting time, etc.
18. Graph indicator in fire control room has history record export feature. 

 
Technical Data
Executive Standard: GB 16806-2006;
Main power: AC187~242,50Hz;
Working temperature: -10c ~50℃
Dimensions: 1245.0mm*800.0mm*545.0mm